The Ohio Supercomputer Center (OSC) is experiencing an email delivery problem with several types of messages from MyOSC. 

Known issues

Unresolved known issues

Known issue with an Unresolved Resolution state is an active problem under investigation; a temporary workaround may be available.

Resolved known issues

A known issue with a Resolved (workaround) Resolution state is an ongoing problem; a permanent workaround is available which may include using different software or hardware.

A known issue with Resolved Resolution state has been corrected.

Known Issues

Title Category Resolutionsort descending Description Posted Updated
2/13/2014 0730 - Reboot of login nodes Outage Resolved

We need to reboot all of the login nodes on our production clusters to fix a minor issue from the downtime. We will be conducting this reboot at 7:30AM on Thursday, February 13th 2014. We expect... Read more

10 years 3 months ago 10 years 3 months ago
Rolling reboot of Owens starting from Oct 10, 2019 login, Owens Resolved

Updated on 1 PM Oct 17, 2019:

The rolling reboot of Owens has been completed. 

Original Post:

We are having rolling reboots of Owens... Read more

4 years 7 months ago 4 years 7 months ago
Issue with submitting job array Batch, Owens Resolved

3:30 PM 5/10/2018 Original Post:

User may have been getting the following error message when trying to submit a PBS job using job arrays:

qsub: submit error (Maximum number of... Read more          
6 years 1 week ago 2 years 5 months ago
Torque module on Oakley improperly setting environment variables Resolved

Intel library paths are being added to the environment variable LD_LIBRARY_PATH incorrectly when loading torque.  Additionally the Intel paths remain when the torque... Read more

9 years 3 months ago 5 years 11 months ago
A partial-node MPI job failed to start using Intel MPI mpiexec Owens, Pitzer, Software Resolved
(workaround)

A partial-node MPI job may fail to start using mpiexec from intelmpi/2019.3 and intelmpi/2019.7 with error messages like

[mpiexec@o0439.ten.osc.... Read more          
3 years 6 months ago 2 years 1 month ago
Negative Balance Emails client portal Resolved

Negative balance emails continue to be sent once an application is submitted.

To confirm whether or not you have truly submitted an application for additional resources and that you can... Read more

5 years 2 weeks ago 4 years 8 months ago
Error when downloading SRA data on computing nodes Owens, Pitzer, Software Resolved
(workaround)

NCBI blocks any connection from computing nodes because they are behind firewalls. Thus OSC users cannot use SRA tools to download data "on-the-fly" at runtime on computing nodes, e.g. 'fastq-dump... Read more

4 years 10 months ago 2 years 1 month ago
VASP job with Out-of-Memory crashes compute node(s) Batch, Owens, Software Resolved
(workaround)

... Read more

7 years 2 weeks ago 2 years 3 weeks ago
Possible performance degradation after August 9th's downtime filesystem Resolved

Updates on May 20 2023:

verbsRDMA is enabled on Pitzer. 

Updates on Dec 14 2022:

verbsRDMA is enabled on Owens during December 13 downtime... Read more

1 year 9 months ago 12 months 3 days ago
Emergency InfiniBand Shutdown (All systems) Network Resolved

We have returned to service. It appears that we have resolved the networking issues enough to allow jobs to run safely. We will continue working with our vendors to fix any remaining hardware... Read more

9 years 9 months ago 9 years 9 months ago