The Ohio Supercomputer Center (OSC) is experiencing an email delivery problem with several types of messages from MyOSC. 

Known issues

Unresolved known issues

Known issue with an Unresolved Resolution state is an active problem under investigation; a temporary workaround may be available.

Resolved known issues

A known issue with a Resolved (workaround) Resolution state is an ongoing problem; a permanent workaround is available which may include using different software or hardware.

A known issue with Resolved Resolution state has been corrected.

Known Issues

Title Category Resolutionsort ascending Description Posted Updated
Correction on OSC project restriction email Account Management Resolved

Updated:

OSC has resolved this morning's issue and reverted impacted projects back to an ACTIVE status. Queued jobs under those projects will be able to start once today's... Read more

2 years 10 months ago 2 years 10 months ago
Oakley login node down Resolved

One of the Oakley login... Read more

9 years 3 months ago 9 years 3 months ago
warning: libhwloc.so.1 may conflict with libhwloc.so.5 Resolved

Sometimes when building MPI programs the following warning appears.  It is harmless and can be safely ignored.

ld: warning: libhwloc.so.1, needed by /usr/local/mvapich2/1.7-intel/lib/... Read more          
9 years 3 weeks ago 8 years 7 months ago
A bug in the trigger that sends automated emails from client portal client portal Resolved

We deployed a new version to OSC Client Portal (my.osc.edu) at 3 pm Tuesday, July 9th, which involves a bug in the trigger that sends automated emails to some OSC clients with the subject 'Your... Read more

4 years 10 months ago 4 years 10 months ago
MOE license server down Licensing Resolved

The MOE license server is experiencing an unknown issue and potentially down.  We are working to resolve the issue.

8 months 2 days ago 8 months 2 days ago
Rolling reboot of compute and login nodes of all clusters, starting from Wednesday morning, March 22, 2017 login, Owens, Ruby Resolved

4:56PM 3/28/2017 Update: The rolling reboots of all systems are completed. 

All compute nodes and login nodes of Owens, Oakley, and Ruby clusters will need to be rebooted... Read more

7 years 2 months ago 7 years 1 month ago
OpenMPI job stopped at 'There are not enough slots available in the system to satisfy the slots' Owens, Pitzer, Software Resolved

Users would encounter a MPI job failed with openmpi/3.1.0-hpcx on Owens and Pitzer. The job would stop with the error  like "There are not enough slots available in the system to... Read more

3 years 10 months ago 3 years 8 months ago
Account changes temporarily suspended Account Management Resolved

We are still experiencing some account problems related to Thursday's issue. As a result, we have taken my.osc.edu offline and cannot process email changes or password resets, either via self-... Read more

9 years 11 months ago 9 years 11 months ago
Rolling reboots of all three clusters, starting from Tuesday, September 4, 2018 Batch, Owens, Ruby Resolved

10:14 AM 09/17/2018... Read more

5 years 9 months ago 5 years 8 months ago
ondemand gpu request error Nov 2021 Batch, OnDemand, Pitzer Resolved

When requesting an interactive session in ondemand and requesting gpu resources, users may see an error similar similar to  "sbatch: error: Invalid generic resource (gres) specification"

... Read more

2 years 5 months ago 2 years 5 months ago